Ws sup720 3b supported line cards. Si vous avez un Supervisor Engine. Ws sup720 3b supported line cards

 
 Si vous avez un Supervisor EngineWs sup720 3b supported line cards  Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin

Processor board ID SMC1041001A SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1. WS-X6148-FE-SFP will require WS-SUP720-3B or VS-S720-10G-3C; WS-X6148-FE-SFP= will require WS-SUP720-3B or VS-S720-10G-3C Customers may be able to use the Cisco Technology Migration Program (TMP) where applicable to trade-in eligible products and receive credit toward the purchase of new Cisco equipment. Hi, I am having a similar case with two redundant SUP720-3B with 512MB of RAM. Is these modules will work with c6509E and these supervisor (VS-S720-10G-3C or VS-S720-10G-3CXL) Yes and no. Additionally, the PFC version on the VS-S720 would have to fall back to PFC-3B to interface with the Sup720. The Modular Cisco Catalyst switches, such as the 6500, 6000, 5500, 5000, 4500, and 4000 Series, support Online Insertion and Removal (OIR) or Hot Swap of all modules (power supplies, fan trays, Supervisor Modules and other Line and Service Modules). Some of these VLANs are propagated to other switches in the network when you use the VLAN Trunking Protocol (VTP). You need a DFC3 to work with the sup720. the Cisco Catalyst 6500/cisco 7600 Series Supervisor Engine 720 Is A Family Of Supervisor Engine (s) Designed To Deliver Scalable Performance And Rich Set Of Ip Features In Hardware. System security is hardened with support for features such as Port Security, CPU rate limiting, Multi-Path uRPF and a long list 802. See this publication for more information:. Buy or Renew. 3fa 10-100 card-wtdr computer networking:SUP7203B PFC incompatibility. The Supervisor Engine 720 family is supported on. Cards per switch. 05-30-2018 01:19 PM. Produkt-Support. 1 Ok. 0 Ok 11. Hope this helps and kindly remember to rate all useful posts. 1 Ok. Table A-3 lists the supported combinations of WS-F6K-DFC3 daughter cards with the Supervisor Engine 720 models and the corresponding functionality levels. 4 Centralized Forwarding Card WS-F6700-CFC SAL11499CPC 4. The WS-X6148X2-RJ-45 (above, left) has 48 physical RJ-45 connectors. VSS — WS-C6513-S32-GE Cisco Catalyst 6513, WS-SUP32-GE-3B, Fan Tray (req. 6509A#show mod Mod Ports Card Type Model Serial No. Note Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720 or WS-SUP720-3B with a PFC3BXL. Supervisor Engine 720 has three uplink ports: two 1000BASE-X Ethernet uplink ports that require the installation of GBIC transceivers and one 10/100/100 port equipped with. Supervisor Engine 720 or 720-3B or Supervisor Engine 2 with PFC2/MSFC2 . 3) with 458720K/65536K bytes of memory. UPC - 746320914848. This CF adaptor-SP comes with more memory size than the older Flash. 512 MB (Memory is located on base module) 2. 3af 10/100, 48 port (RJ21) line card . 4 (2) SP rommon version to get the internal flash disk recognized and I only have one card at 8. WS-SUP720-3B WS-SUP720 . These are the Supervisor Engine 720 features: 1. 2 (1)SY supports only the hardware listed in the “Supported Hardware” section. 2 Distributed. 10G-3C, Select 67xx Line Cards, and Accessories. hardened with support for features such as Port Security, CPU rate limiting. Sup720/3B/3BXL 10-28-2020 10:02 AM. Is the WS-SUP720-BASE line card a fully supported module in the 6509-E chassis? In the meantime I'm gonna keep looking. Thanks both, The linked page helped, now I have: Chassis#1 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1002A4BQ 6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD090303EU 5 0014. Product Code WS-SUP720-3B= WS-SUP720. 4 PwrDown. 2 Ok. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B . Quick Links Contacts;. 5 Ok. 5 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAD0AAAAAAA. 1 Ok 5 MSFC3 Daughterboard WS-SUP720 SAD092607JG 2. At the same time, MEM-MSFC2-512MB=, the description shows, MSFC3. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B,. WS-F6700-DFC3A . rommon 2> Set. hello all i need help to see what is the problem of this router. WS-SUP720-3B sup is EOL as well. 7) and later . 3 Centralized Forwarding Card WS-F6700-CFC SAL1425KQGX 4. . WS-SUP720-3B SAL1224TWT2. Redundant Supervisor Engines must be of the same type with the same model feature card to support redundancy. 4 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 . 1 Ok. 1x extension. When I power the unit on, the new supervisor comes up and working, but the 10G modules go to "PwrDown" state after some errors. ) I have WS-SUP720-3B and compact flash. However, during the careful installation I noticed that the thorn d. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAXXXXXXXXX. Deploy high-performance IP/MPLS features as well as scalable personalized IP services at the network edge, improve operational efficiency, and maximize return on network investments with the Cisco 7600 Series Router. Condition: New Availability: 0 Reliability and. Talk to your SE/AM. 7 Policy Feature Card 3 WS-F6K-PFC3BXL SAD083305A1 1. 5 Ok. Mod MAC addresses Hw Fw Sw Status. The system is a 6509-E running software version 15. We are getting new 10Gig connection (It will be 1gig until we will upgrade our supervisor blade) from our ISP. WS-SUP720-3B - Supervisor Engine 720 network router pdf manual download. I can say for certain the ASICs responsible for the switch fabric are different, and they have different mechanisms for syncing up the fabric. Technology and Support; Networking; Routing; 6509E and Sup720; Options. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. show power and show modules follow: #show power system power redundancy mode = redundant system power total = 2771. Save this manual to your list of manuals. (WS-SUP720-3B) SUP 720 with MSFC3 & PFC3BXL (WS-SUP720-3BXL) 8. WS-SUP720-3B: 15310-CTX-2500-K9: WS-X6548-GE-45AF: 15454-OC192L-1-32. About three weeks ago, Cisco IOS 15. We have a pair of 6509 E Cat Switches and now we need to implement VSS. *Apr 18 06:57:37. The supervisor supports FAT 12 and 16. I believe we have 6708 line cards working with both sup720-3Bs and VS-S720s. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. Supervisor Engine 2 Product Number. Multiple daughter-card options for incremental upgrades and backward compatibility to support multiple generations of interface modules. The last date to receive service and support for the product. It goes out the port of the same card/slot with DSCP 0. . The SP ROMMON is 8. Are the WS-X6148-GE-TX and WS-X6148A-GE-TX compatible with WS-X6K-SUP1A. Buy or Renew. It will handle all the control-plane and management plane. u Beginner 11-10-2021 01:13 PM I bought a WS-C6509 chassis for a trainee and test lab, it. The refurbished Cisco WS-SUP720-3B Supervisor engine 720 integrates a high-performance 720 Gbps crossbar switch fabric with a forwarding engine in a single module, delivering 40 Gbps of switching capacity per slot (enabling 4-port 10GE and 48-port 10/100/1000 density line cards). Hello, I am a intern that was tasked with swapping out a supervisor 720-3b that has to be sent out for rma, and I already received the replacement from Cisco. 1 Ok. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAXXXXXXXXX. rommon 6 > dir slot0: >>> Beliving that you have image on the slot0 ( (the device ID is slot0: and/or slot1:, corresponding to the PCMCIA cards inserted in the respective slots):6 2 Supervisor Engine 720 (Hot) WS-SUP720-3B SAL11477L4J The device is operating so we'are creating low impact towards the environment. Cisco Catalyst Switches der Serie 6500. Customers Also Viewed These Support Documents. Laurent. 6 Ok. Hi, we are using 12. 2(121) or later on the Cisco SAMI. 03-09-2011 02:46 AM. 5(1), IOS 12. Options. 1 Ok 10 Centralized Forwarding Card WS-F6700-CFC SAXXXXXXXXX 2. Note Supervisor Engine 32 does not support this hardware: • WS-SUP720-3B • WS-F6K-PFC3BXL—Policy Feature Card 3BXL (PFC3BXL) • Distributed Forwarding Cards (DFCs) (installed DFCs do not power up with a Supervisor Engine 32) • Switch Fabric Modules • These switching modules: – WS-X6704-10GE—4-port 10-Gigabit Ethernet XENPAK –. 2. Which brings up another question for me: Can you use any of the DFC3s (WS-F6700-DFC3B, WS-F6700. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3BNo recent hardware/software changes have been made. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. For the RSP720 to interoperate with lower-version cards, the system determines the lowest operating mode of all installed cards (3B, 3BXL, 3C, or 3CXL) an d applies this mode to all of the cards. 0 Ok. † Supervisor Engine 32 does not support this hardware: – WS-F6K-PFC3A. WS-X6148A-45AF. . Media Type Supported: Twisted Pair: Ethernet Technology: Gigabit Ethernet: Network Technology:. 3AF inline power. WS-SUP720-3B: PFC3B mit 512 MB DRAM MSFC3 MIT 512 MB DRAM und 64 MB Bootflash: 12. View solution in original post. UPC - 746320914848. 0 % First-trip repair success. Table 1. i have 2 ws-c6509-e whit each one your sup720-3b. Can we upgrade the sup 720 to Sup 2T. 1-Sy7(MD) (What will be the upgrade path and how many time chassis will be a reboot in this process). Actions performed: 1) Reboot 2) Re-seat the module. If they rebrand the Sup2T as RSP2T, they would have close to no supported line cards (only 67xx without DFCs) and, specifically, all of the high-functionality line cards (ES+) wouldn't be supported. The variants of PFC3 distinguish the various Supervisor 720 families of engines. MPLS in hardware to enable use of layer 3 VPNs and EoMPLS tunneling. SXJ2. Our log files don't indicate anything leading up to the incident. Note The VSPA does not support OSM modules. 4864 bytes copied in 2. 2(33)SRB4?. VS-S720-10G-3CXL, WS-Sup720, WS-Sup720-3B, and WS-Sup720-3BXL. 5 12. Q. 5) with 458720K/65536K bytes of memory. 2 Centralized Forwarding Card WS-F6700-CFC SAL114140WX 4. . Victoria Clipper V. 3 Ok 3 Distributed Forwarding Card WS-F6700-DFC3BXL xxxxxx 5. Ethernet Services Line Cards; Online Diagnostic Tests; Acronyms; Search Find Matches in This Book. 4(2) on. Table A-3 lists the supported combinations of WS-F6K-DFC3 daughter cards with the Supervisor. We're thinking of using SSO mode but we read that when I reset the standby Supervisor Engine the version mismatch message brings about a reload all modules (Redundancy Mode changes from. 6 MSFC3 Daughterboard WS-SUP720 SAL1015JMXX 2. This two cards installed in cat6509E. De modulaire Cisco Catalyst switches, zoals de 6500, 6000, 5500, 5000, 4500 en 4000 Series, ondersteunen online installatie en verwijdering (OIR) of Hot Folder van alle modules (voedingen, ventilatormodules, Supervisor modules en andere lijnen en servicemodules). End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories 06/Jan/2015. It is not recommended to use them. 07-15-2011 12:54 AM. . After this date, all support services for the product are unavailable, and the product becomes obsolete. Hi everybody. %ONLINE-SW2_SPSTBY-6-REGN_TIMER: Module 7, Proc. On the Catalyst 6500/SUP720 that runs Cisco IOS, the SP will boot first and will then switch ownership to the RP. It can also be used as a regular 48 ports 10/100 line card in a first deployment stage with the possibility of extending to a future 96 ports of 10/100. The switch will not change the operating mode (3A/3B/3BXL) by itself during runtime (unless the following OIR happens). (and other redundant cards) without powering down the router. hi, I've 2 x 6509-E chassis. 4 feet. 8 Centralized Forwarding Card WS-F6700-CFC SAL16138HQL 4. Save. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink;. 6 OkGraphic Cards. Bevor Sie beginnen Anforderungen. 971: %OIR-SP-3-PWRCYCLE: Card in module 2,. 0. the Integrated 720-Gbps Switch Fabric 2. Its hardware-based set of features allows for the deployment. Step 3 Remove the Supervisor Engine 720 from the Catalyst 6500 series switch. -Targeted IOS upgrade 12. See. Everyting appears to be working correctly accept the detection of the bootdisk (Internal flash). 2-WS-SUP720-3B : Catalyst 6500/Cisco. On any modules running Cisco IOS software, save the running configuration. By Brand. 5 Policy Feature Card 3 WS-F6K-PFC3B SAL1225UDJ0 2. The WS-F6K-DFC is only supported on the sup2. When the RP gains control you will see a message that looks like this: After you see this message, press Ctrl+BREAK until you see the rommon> prompt. Laurent. SUP32 and SUP720 for 10G - We are looking at upgrading our SUP2 to SUP32 and SUP720 with 10G capability. The other model has 6500-E chassis , FWSM and Sup 720 . 2, 512KB L2 Cache Last reset from power-on 75 Virtual Ethernet interfaces 122 Gigabit Ethernet interfaces 16 Ten Gigabit Ethernet interfaces 1917K bytes of non-volatile configuration. the 3B relartes to the model of PFC card that is installed on the sup720. Each chassis has the follow modules: slot1: WS-X6724-SFP slot5: WS-Sup720-3B I would like to create a dot1q etherchannel bundle btw the two chassis using the Sup720-3B & line cards. DFC3BXL supports one million routes Deployed in CEF720 line cards such as WS-X6704-10GE, WS-X6724-SFP, WS-X6748-SFP, and WS-X6748-GE-TXJoseph, Thanks also for your reply and useful information. Save this manual to your list of manuals. According to logs my VLS link went down and one of switch has rebooted. meanwhile i have formatted a compact flash in the one that are working fine cop. Chinese; EN US; French; Japanese; Korean; Portuguese; Log InWhen I have a catalyst 6506 with a sup720 engine: WS-SUP720-3B. Memory: 512MB CompactFlash (CF) Card Supported Cisco WS-SUP720 Environmental Conditions: Temperature: 32 degrees F (0. Thank you! You can boot it up in rommon (normally ctrl+c when it boots) and enter "confreg 0x2142" and then just type reboot. Table 1-7 lists the serial line card and module support for each release. It's pretty self explanatory for a tec. -Installation for new Sup 2T. What platforms and Cisco IOSes support MPLS? A. 2, 512KB L2 CacheI´m experiencing a weird problem with a Catalyst 6509, 2XSUP7203BXL and 2XWS-X6704-10GE. I believe this is the final release for WS-SUP720-3B which was launched in 2004, and VS-SUP720-10G-3C which. We've got dual SUP-720-3B modules with PFC3 daughter cards, which looks like it's supported, but I was hoping someone has done this and can confirm it is accurate, and any caveats or gotchas that people have come across. Up to 1024 VRFs with a total of up to 256,000 routes per system. Symptoms: The standby WS-SUP720-3BXL failed to boot into SSO mode because of. rommon 3> confreg 0x2102. This version of Supervisor Engine 2 supports only the Catalyst operating system; it does not support Cisco IOS. 1Q2T shared between 8 ports. SXF6. PFC3의 종류에따라 Supervisor 720 엔진 제품이 구분되는데, WS-SUP720, WS-SUP720-3B 및 WS-SUP720-3BXL에 해당하는 세 가지 선호 제품(PFC3A, PFC3B, PFC3BXL)이 있습니다. 10G-3C, Select 67xx Line Cards, and Accessories. Jun 27, 2012, 3:48 PM Post #1 of 27 (16773 views) Permalink. The CEF256 and dCEF256 series modules connect to fabric using 8 Gbps per channel and CEF720 series modules connect to it using 20 Gbps per channel. Mod Online Diag Status---- -----. Mod Online Diag Status---- -----2 Pass 3 Not Applicable. 16 port dCEF256 Gigabit Ethernet interface module for the Cisco Catalyst 6500 Series switches with dual fabric channel interfaces and. The CF-Adaptor-SP is the adaptor, this comes as the. SFP modules). WS-X6148A-GE-45AF. Here are the steps: rommon 1 > dev. Supervisor Engine 720 제품군은 Cisco Catalyst OS® 및 Cisco IOS® 운영 체제 모두에서 지원됩니다. Mô Tả: Mô-đun quản lý động cơ giám sát WS-SUP720-3B Catalyst 6500 /. rommon 5> reset. Feature Card 3B (WS-SUP720-3B) – Cisco 7600 Series Supervisor Engine 720 with a Multilayer Switch Feature Card 3 and Policy Feature Card 3BXL (WS-SUP720-3BXL) – Cisco 7600 Series Supervisor Engine 32 with a Multiplayer Switch Feature Card (WS-SUP32-GE-3B) with LCP ROMMON Version 12. It will help me collate a good response to our customer. hotStandby support. The description of the line item,MEM-MSFC3-1GB says "1GB Mem for Sup720, Sup720-3B and MSFC2A" So that should take care of the SP (sup engine) but doesnt look like MSFC3 is supported. Those ports (there should be two), on a sup720, are really intended more as management ports. 1 Ok. It can be used with the WS-F6K-48X2-SPLTR (above, right) as a 96 port 10/100 line card. The PoE daughter cards can be installed either at the factory or in the field on select 10/100 and 10/100/1000 Ethernet switching modules to upgrade the Ethernet switching modules. delivering 40 Gbps of switching capacity per slot (enabling 4-port 10GE and 48-port 10/100/1000 density line cards). The compatablity matrix (see below) states that 67xx cards are supported but it goes on to state DFC3C or DFC3CXL cards are n. After installing MWAM the Status is PwrDown. All the 4 lights on the card are still showing as orange and the 'show mod' output shows the following: This means the line card has gone into ROMmon. 1 Ok. DWDM-XFP modules supported in SPA-1X10GE-L-V2 on SIP-600. ** DFC3 daughtercard options are WS−F6700−DFC3A, WS−F6700−DFC3B, WS−F6700−DFC3BXL, WS−F6700−DFC3C, or WS−F6700−DFC3CXL. 3 feet, width: 40. 65. Using show module the online daig status is unknown and the detals for the card are as follows: HW FW Sw Status. SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1. I understand the WS-F6700-CFC card is required for each of those line cards to support this. 1. We are planning to buy VS-S720-10G-3C to replace with the current SUP720-3B. If the line card supports it, you probably want a WS-F6700-DFC3B. -Installation of new C6800-32P 48ports module. 3 Ok. It will get stuck at booting from the SP. Page 28 highlights. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Switches. 0 Ok 2 Centralized Forwarding Card WS-F6700-CFC SAL1026TF24 2. Policy Feature Card 3BXL (PFC3BXL) Supported only with Supervisor Engine 720. 5 PwrDown. Maximum distance is 10km (32,810 ft). So this means if we want Sup 2T's, we'll also need to replace all the 6708's that are still in great shape. 10G-3C, Select 67xx Line Cards, and Accessories EOL9892 - Amended. I have changed the default boot file to a bootable image, which works when prompted at ROMMON. 122-18. 2 MB shared between 8 ports. 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B. 0 Ok 5 Policy Feature Card 3 WS-F6K-PFC3B SAD0927056R 2. 6 16 SFM-capable 16 port 10/100/1000mb RJ45 WS-X6516-GE-TX SAXXXXXXXXX The 4-port 10 Gigabit Ethernet fiber module (Figure 4) has no oversubcription and is designed for deployments in which line rate is important. Is there something else. Presales have scoped 4x VS-S2T-10G cards to perform a seamless upgrade on the secondary unit first and then the primary. (If not yet announced, then it will be shortly. We want to have cisco expert point of view, do these Supervisor card (WS-SUP720-3BXL and WS-SUP720-3B) support or not support VPLS ? note that we are running also s72033-adventerprisek9_wan-mz. Talk to your SE/AM. all of the high-functionality line cards (ES+) wouldn't be supported. Since you are already in privilege !--- mode, the passwords in this configuration (that are not known) do not affect you. and PFC3BXL, correspond to WS-SUP720, WS-SUP720-3B and WS-SUP720-3BXL. We are trying to limit an internal subnet (/24) to a bandwidth limit of 15 mbps during the week day time. We have a pair of 6509 E Cat Switches and now we need to implement VSS. They could be the following: 4. Using the compact flash adaptor, I did boot SUP. Get 90 Days Seller Warranty, 24/7 Tech Support & Quick Shipping to your Doorstep in India-Mumbai, Delhi, Hyderabad, Goa, Agra, Vizag, Hyderabad, Bangalore, Pune, Gujarat, Maharashtra, Nagpur, Noida, Jaipur,. After I "downgraded" the IOS to our baseline, I cannot read from the sup-bootflash. I also have following line cards and not srue if they are also EOL. If you reach this limit, the switch does not allow further vty sessions. QoS, multicast packet replication and security policies. EOS for Selective Cisco Catalyst 6503,Catalyst 6506 and Catalyst 6509 Chassis 08/Jan/2014. It was very helpful. Interface Cards ; WS-SUP720-3B Catalyst 6500/Cisco 7600 Supervisor Engine Management Module (WS-SUP720-3B=) Zoom the image with the mouse . 5 Ok. HTH. 1000. Cisco Catalyst 6500 Supervisor Engine 720 (WS-SUP72 0-3B and WS-SUP720-3BXL)7600 w/ WS-SUP720-3B IOS 15. WS-SUP720-3B is the Routing processor of the chassis (the brain if you want). This line card not support . WS-F6700-DFC3B . This table lists the maximum number of unique HSRP group IDs supported (system wide) on various Supervisor Engines with MSFC1, MSFC2, MSFC3 (Supervisor Engine 720), or MSFC2A (Supervisor Engine 32). WS-X6724-SFP. 1 (1)SY on both active and backup supervisor modules. My company has recently bought a VS-S720-10G-3C to replace with old sup720-3b, we have a 6509-E with two "WS-X6704-10GE (WS-F6700-CFC)" on slots 1&2. Thank you. If a line card with DFC3B is inserted into a switch with SUP720-3BXL, the line card does not power up. We purchased a supervisor 720 (WS-SUP720-3B) and (2) (WS-6708-10G-3C) 8 port fiber modules and (1) WS-X6748-GE-TX) 48 port module to add to the switch. Note:. Hall of Fame Community Legend. Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions: Lower than 5. You can add, replace, or remove modules without interrupting the system power or causing other software or interfaces to shut down. WS-SUP720-3B Supervisor Engine 720 with PFC3B: Switch processor (SP):. . Cisco Catalyst WS-SUP720-3B Supervisor Engine Module Repair Service Center. I have no problem with classic cards like WS-X6416-GBIC (16 port fiber module). Solved: Hello, We have a Catalyst 6509 ( WS-6509-E) with WS-SUP720-3B supervisor engine. 64-MB bootflash device or CompactFlash adapter with 512 MB CompactFlash card (WS-CF-UPG=): 3. The Supervisor Engine 720 family is supported on both operating systems–Cisco Catalyst OS3 Distributed Forwarding Card WS-F6700-DFC3C SAL1333WCAL 1. 0 Ok. 1 Distributed Forwarding Card WS-F6700-DFC3C SAL1228WULV 1. Use the command show bootvar to check that the boot variable is the same on both SUPs. package directory path argument in the upgrade fpd path. 5 Ok 7 IDS 2 accelerator board WS-SVC-IDSUPG ADBG6390007 2. But I forgot its password, so I tried to recover password , FAILED First of all, I entered ROMmon mode using Ctrl+Break, and then enter "confreg 0x2142" command. This is the result of the "show power" command. 3 Ok. Sie können Module hinzufügen, ersetzen oder entfernen, ohne die. Slot Card-Type Watts A @42V Watts A @42V State StatePage 36 Modular Switches: Cisco Catalyst 6500 Series Supervisor Engines Hardware Features Virtual Switching Supervisor SUP 720 SUP 32 SUP 32-PISA 720-10G VS-S720-10G-3CXL WS-SUP720-3BXL WS-SUP32-10GE-3B WS-SUP32-10GE-PISA VS-S720-10G-3C WS-SUP720-3B WS-SUP32-GE-3B WS-SUP32-GE-PISA Chassis Supported. I am going to be performing an upgrade to the flash on my Core 6506-E switch. 5 (3), all others are at 8. See. Supervisor Module 720----WS-SUP720-3B. That seems to be the reason. 2 (1) Supervisor II with Cisco IOS Software Release 12. There are three flavors, PFC3A, PFC3B and PFC3BXL, correspond to WS-SUP720, WS-SUP720-3B and WS-SUP720-3BXL. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3BXL . In order to use DFC3A-equipped switching modules with a PFC3BXL or PFC3B, the DFC3A-equipped switching modules must be installed at boot up. 2, 512KB L2 Cache Last reset from s/w reset SuperLAT software (copyright 1990 by Meridian Technology Corp). 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SALxx. 3 do not power up. 16 Watts (65. rommon 5> reset. If a line card with DFC3B is inserted into a switch with SUP720-3BXL, the line card does not power up. I am going to be performing an upgrade to the flash on my Core 6506-E switch. However, continuously entered rommon mode. SXJ7. Die modularen Cisco Catalyst Switches wie die Serien 6500, 6000, 5500, 5000, 4500 und 4000 unterstützen das Online Insertion and Removal (OIR) oder den Hot Swap aller Module (Netzteile, Lüftereinschübe, Supervisor-Module und andere Line- und Service-Module). The full BoM is as below: VS-S2T-10G= Cat 6500 Sup 2T with 2x 10GbE and 3x1GbE with MSFC5 PFC4. 2(17d)SXB1 and later WS-SUP720-3BXL supports Cisco IOS 12. 6 MSFC3 Daughterboard WS-SUP720 SAL1424KCMQ 4. Yes, they could support 68xx and 69xx and spin new ES cards (ES++), but that would be fairly expensive. Many thanks John Thanks for the reply and useful info. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories. Web Hosting TalkFor additional supported and unsupported module lists, refer to these Release Notes. 3 Ok 6 IEEE Voice Daughter Card WS-F6K-GE48-AF SAL09316N0Q. I already purchased a FAN tray, two power units and 3 line cards (2x mini GBICs, 1x RJ54 ports). 7 Centralized Forwarding Card WS-F6700-CFC SAL1611704A 4. Cisco Catalyst 6513, WS-SUP32-GE-3B, Fan Tray (req. WS-X6548-GE-TX. 6 6 Firewall Module WS-SVC-FWM-1 SADxx. When inserting higher performance mode line card, while under lower. 6 OkCisco WS-SUP720-3B Processor Guide - Page 58. 2 512 MB is standard. 3 Ok. e. Solved: Heloo experts, Fro the doc, it apears that 16port copper module supported by 6513 chassis with 720-3B sup. [code] View 5 Replies Similar Messages: Cisco WAN :: SUP720-3BXL / Using Of ECC Or Plain Memory? Cisco WAN :: WS-SUP720-3BXL And WS-X6748-GE-TX Configuration; Cisco WAN :: 7613 - Redundancy With WS-SUP720-3BXL ModuleTechnology and Support; Networking; Switching; 6509 stuck in Rommon mode; Options. Linecard showed status as. I could configure SSO in the switch. You need a DFC3 to work with the sup720.